ttyu0113 publicou uma atualização 3 anos, 10 meses atrás
KC-SCT manufactures seamless stainless steel pipes conforming to ISO/EN standards, and delivers them to each customer through natural gas annealing and pickling processes. Some pipes can be delivered through protective atmosphere annealing (bright annealing) processes. Customers need to give us a clear explanation.
1. Material
Several materials in austenitic stainless steel.
2. Cold processing technology
The combination of cold rolling and cold drawing helps to improve the consistency of the pickling color of the inner and outer surfaces of the pipe, and ensures that the inner and outer surfaces are smooth and delicate, and a high-quality metallographic structure can be obtained after annealing.
3. Production standards
EN 10216-5 TC1
PED 97/23/EC, AD 2000
4. Product specifications
OD
mmThickness WT
1.01.21.62.02.32.62.93.23.64.04.5
kg/m
13.50.3140.3710.4780.5780.647
17.20.4070.4820.6270.7640.861
21.30.5100.6060.7920.9701.098
26.90.6510.7751.0171.2511.421
33.7
0.9801.2901.5931.8142.0312.2442.452
42.4
1.6402.0302.3172.5992.8773.1513.5093.858
48.3
1.8772.3262.6582.9853.3073.6254.0424.4514.951
60.3
2.3592.9293.3513.7694.1814.5905.1275.6576.308
76.1
4.2644.8005.3325.8606.5567.2458.094
88.9
5.0035.6366.2656.8897.7148.5319.541
114.3
7.2958.1158.93110.01111.08312.412
-The OD-WT with weight display can be customized
5. Tolerance
Tolerances according to EN ISO 1127
ConditionOutside diameterWall thickness
Cold workedD3:+/- 0.75%, with +/-0.3mm min
D4:+/- 0.5%, with +/-0.1mm minT3:+/- 10%, with +/-0.2mm min
T4:+/- 7.5%, with +/-0.15mm min
6. Surface delivery status
ISO/EN seamless stainless steel pipes are available in two delivery states:
6.1 Solid solution pickling: delivery after natural gas heat treatment, pickling passivation.
6.2 Bright Annealing: After the atmosphere protection heat treatment, it can be delivered without pickling. The specific content needs to be negotiated with the purchaser!
7. Non-destructive inspection
Each stainless steel pipeline is tested according to the standard of water pressure testing and eddy current testing:
Hydrostatic pressure detection: maximum pressure 20Mpa, time 5 seconds
Eddy current flaw detection: Perform inspection according to standard sample tube, which meets standard EN 10246-2.
8. Other inspections
For heat exchanger pipes, sampling inspections such as stretching, flattening, flaring, grain size, and hardness are carried out in accordance with the standards.DIN EN ISO Pipes manufacturers
website:http://www.kcsteelpipe.com/stainless-steel-tubes/din-en-iso-pipes/