Mounting and operating instructions for room thermostats
The device may only be opened and installed according to the circuit diagram on the device or these instructions by a qualified electrician. The existing safety regulations must be observed. Appropriate installation measures must be taken to achieve the requirements of protection class II. This independently mountable electromechanical or electronic device is designed for controlling the temperature in dry and enclosed rooms only under normal conditions. The device confirms to EN60730, it works according operating principle 1C.
The switching point is lower when temperature control knob is turned than in automatic operation. The exact switching point is reached only after a climatisation period of approx. 1-2hours.
Relative humidity ————————————————————————— max. 95% without condensation
Rated impulse voltage ———————————————————————4KV
Ball pressure test temperature ———————————————————–75+/-2鈩?/p>
Voltage and current for the purposes of interference measurements ———-230V; 0.1A
Pollution degree ——————————————————————————2
Energy class ———————————————————————————-1=1%
(acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
Remark:Customized Underfloor Heatting System Thermostats
website:http://www.zjsade.com/thermostats/underfloor-heatting-system-thermostats/